Rice Lake RL75016 Alloy Steel, Double-ended Beam Load Cell

As of: Wednesday, September 9, 2026
Save or Print to PDF
rl-RL75016-load-cell

Standard Features

This is an alloy steel, double-ended beam load cell with center loading, ideal for tank and hopper applications. The capacities are available from 1,000 to 75,000 pounds, and each module is complete with 25 feet of load cell cable.

Approvals

LOGO FM CUS

WARNING: Cancer and Reproductive Harm California Proposition 65

RL75016 Load Cell Specifications

Full Scale Output:
3.0 mV/V 

Output Resistance:
700 (± 5) ohm

Input Resistance:
770 (± 10) ohm

Material/Finish:
High-alloy steel, nickel plated

Temperature:
Operating:
0 to 150 °F (-18 to 65 °C)

Seal Type:
Environmentally sealed, IP67

Safe Overload:
150% full scale

Safe Sideload:
100% full scale

Rated Excitation:
5 to 10 VDC (15 V maximum)

Nonlinearity:
0.03% full scale

Hysteresis:
0.02% full scale

Insulation Resistance:
5,000 megohm

Deflection at Capacity:
1,500 lb: 0.01 in
15,000 to 20,000 lb: 0.022 in

Cable Length:
25 ft

Cable Diameter:
0.200 in 
Polyurethane jacket

Cable Color Code:
Red +Excitation
Black -Excitation
Green +Signal
White -Signal

Warranty:
Two-year limited

Approvals:
cFMus

RL75016 Load Cell Dimensions

1000-20,000 lb

Rated Capacity A1 A2 C D E F
lb/in
1,500 0.50 1.25 1.25 1.25 7.50 6.25
15,000 to 20,000 0.81 1.99 1.44 1.94 8.75 7.50

 

 

Parts

Part # Description
17302 Load Cell,DEB RL75016-1.5 K 1,500 lb 25ft 3mV/V 700 OHM WW IP67 FM
17313 Load Cell,DEB RL75016-15K 15,000 lb 25ft 3mV/V 700 OHM WW IP67 FM
17315 Load Cell,DEB RL75016-20K 20,000 lb 25ft 3mV/V 700 OHM WW IP67 FM

Rice Lake 800-472-6703