Rice Lake RLSCA-50K Stainless Steel, Rocker Column Load Cell
Standard Features
This is a replacement for the Cardinal® SCA products. The RLSCA-50K features an IP67 rating, stainless steel construction and welded sealing to provide environmental protection. This includes a load cell and two retrofit cups that are compatible with various applications. It's NTEP Certified, easy to install and access, available in a 50,000-pound capacity and equipped with 30 feet of standard load cell cable.
RLSCA-50K Load Cell Specifications
Full Scale Output: Output Resistance: Input Resistance: Material/Finish: Temperature: | Seal Type: Safe Overload: Rated Excitation: Combined Error: Non-repeatability: Insulation Resistance: | Cable Length: Cable Diameter: Cable Color Code: Warranty: Approvals: |
RLSCA-50K Load Cell Dimensions

| Rated Capacity | A | B | C | D | F | H | I | J | K |
|---|---|---|---|---|---|---|---|---|---|
| lb/in | |||||||||
| 50,000 | 1.46 | 7.75 | 7.25 | 2.82 | 1.70 | 0.50 | 0.25 | 1.48 | 2.50 |
Parts
| Part # | Description |
|---|---|
| 68918 | Load Cell,CSR RLSCA-50K 50,000lb 30ft 2mV/V 1050 OHMS EW SST WS NTEP III L 10M (includes top and bottom cups) |
![]()
An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems