< No response from tray detector (1502)

|
Error content |
No response has been received from the detector. |
|
Detail |
Communication between the console and the detector has not been performed. The sub-error includes the communication phase number. A communication error immediately after the completion of power-on processing will cause this error. |
Solution |
Press [STOP] to disconnect the communication with the detector. Operation is possible without label applicator. Press the [REEXEC] button to check the connection with the detector. Release the error after confirming the connection. |
User’s action |
|
Service person’s action |
Check the RS485 communication line of the main board (P-100, P-1100, P-1163). Check the RS485 communication line [A221 XJ-11] and the DC 24V power supply [A221 XJ-9] of the detector board. |
Related part |
Main board (P-100, P-1100, P-1163) [A10] Detector board (P-1107) [A221] The following RS485 communication has not been established: Between P-1107 [A221] (XJ11) and P-1163 [A10] (XJ4) |
|
Remarks |
|