< Blackout for the console (604)

|
Error content |
Power failure detected in the applicator. |
|
Detail |
Power ON notification command was received twice from the console. |
|
Solution |
Restore power |
|
Action by user |
|
|
Action by service representative |
|
|
Related part |
① 24 V DC to the power supply (XJ12) of P-1105 [A100]. ② RS485 communication cable between main boards (P-1100, P-1163, P-1000) [A10] and P-1105 [A100]. |
|
Remarks |
|